Filter Results By:

Products

Applications

Manufacturers

Showing results: 106 - 120 of 166 items found.

  • Micro probes 1 MHz up to 6 GHz

    MFA 01 set - Langer EMV-Technik GmbH

    The micro probes are used to measure magnetic fields and they have a high resolution. They measure magnetic fields up to 6 GHz, e.g. at signal conductors (150µm), SMD components (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the Bias tee BT 706. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee BT 706 to a spectrum analyzer or an oscilloscope. Langer EMV-Technik GmbH includes correction lines in the delivery. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.

  • Micro probes 1 MHz up to 1 GHz

    MFA 02 set - Langer EMV-Technik GmbH

    The two in the set included micro probes are used to measure low-frequency magnetic fields up to 1 GHz, e.g. at signal conductors (150µm), SMD componets (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the BT 706 Bias tee. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee to a spectrum analyzer or an oscilloscope. The MFA 02 set delivery of Langer EMV-Technik GmbH includes correction lines. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.

  • Ultra Low Noise Preamp

    J2180A - PICOTEST Corp.

    The J2180A low noise preamplifier provides a fixed, AC coupled 20dB gain while converting a 1 MOhm input impedance to a 50 Ohm output impedance. With a 3dB bandwidth of 0.1Hz to 100MHz, the preamplifier improves the sensitivity of oscilloscopes, network analyzers and spectrum analyzers while reducing the effective noise floor and spurious response. The preamplifier can also serve as a low frequency DC blocker for a spectrum analyzer or you can use it to connect a high input impedance oscilloscope probe to 50 Ohm equipment.

  • Acute 4GS/s 68 Channel Logic Analyzer With 32Gb Memory

    Acute LA3068B+ - TEAM SOLUTIONS, INC.

    *LA3000E+/B+ series logic analyzer*PC-based*68 / 136 channels*USB 3.0 interface, 12V power adaptor*4GHz Timing Analysis / 250MHz State Analysis*32Gb RAM*Active Probes*Logic, State, Protocol triggers

  • Controlled Impedance Analyzers

    Hyperlabs, Inc.

    HYPERLABS Controlled Impedance Analyzers can be used with various probes and adapters to quickly and reliably characterize impedance on PCB test coupons. These Test Systems are designed to comply with IPC-2141A standards for PCB coupon testing, and can be customized to meet specific customer needs.

  • 3000A Current Flexible Clamp Probes

    Extech PQ34-30 - Extech Instruments Corporation

    The Extech PQ34-30 is a set of 3000 A Flexible Current Probes for PQ3450/PQ3470 power quality analyzers. It has a 61 cm (24 in) length for wrapping around bus bars and wire bundles. Switch between 3 ranges: 3000 A, 300 A, and 30 A.

  • Near Field Probes 30 MHz up to 3 GHz

    RF6 set - Langer EMV-Technik GmbH

    The RF6 near field probe set consists of 2 passive magnetic field probes and 2 passive E field probes for measurements in the development phase of the E-field and magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF6 set allow a step by step localization of interference sources of the RF magnetic field and RF-E-field on an assembly. From a larger distance the electromagnetic interference is detected by RF-R 50-1 for the magnetic field and by RF-E 02 for the E-field. The RF-B 3-2 and RF-E 10 probes with their higher resolution can more presicely detect the interference sources of the magnetic field and the E-field. Field orientation and field distribution on an electronic assembly can be detected by special guidiance of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.

  • Gasmet Portable FTIR Ambient Gas Analyser

    DX4030 - Quantitech Limited

    The Gasmet DX4030 was the first truly portable FTIR gas analyzer in the world. The lightweight analyzer module is located in durable Teflon–coated backpack. The DX4030 analyser module houses a Fourier Transform Infrared (FTIR) spectrometer, Rhodium-Gold coated sample cell and signal processing electronics. The sample gas is extracted into the sample cell via a probe with built in a particle filter. Hence no sample preparation is needed.

  • Active Differential Probe, 100 kHz to 7 GHz

    U1818A - Keysight Technologies

    The Keysight U1818A 100 kHz to 7 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818A allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.

  • Active Differential Probe, 100 kHz to 12 GHz

    U1818B - Keysight Technologies

    The Keysight U1818B 100 kHz to 12 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818B allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.

  • Near Field Probes 1GHz - 10 GHz

    SX set - Langer EMV-Technik GmbH

    The SX1 set consists of 3 passive near field probes for making measurements in the development phase of E-field and magnetic field with a high clock frequency in the range from 1 GHz to 10 GHz. The probe heads of the set SX allow for measurements close to electronic assemblies, e.g. on single IC pins, conducting paths, components and their connectors, to localize interference sources. Field orientation and field distribution on an electronic assembly can be detected through trained use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They have an internal terminating resistance.

  • In-situ Gas Analyzers

    SICK Sensor Intelligence

    Real-time gas analysis directly within the processInnovative measurement technology that allows the devices to be mounted directly at the measurement site: In-situ gas analyzers take measurements directly within the process under system conditions. These analyzers are primarily characterized by their minimal maintenance requirements and extremely short response times. SICK's in-situ gas analyzers are available in two different versions:The cross-duct version for representative measurement results across the entire duct diameterThe measuring probe version, optimized for single-sided gas duct installation

  • Protocol Analyzer

    PGY-SSMlite SD - Prodigy Technovations Pvt. Ltd.

    PGY-SSMlite SD Protocol Analyzer is the most feature rich comprehensive Protocol Analyzer available to capture and debug SD protocol data. PGY-SSMlite Protocol Analyzer supports SD, Protocol analysis for wide data rate up to 200MHz SDR mode (UHS-I). The innovative active probe has minimum electrical loading on device under test (DUT) and allows the protocol data capture without affecting the performance DUT. PGY-SSMlite protocol analyzer allows industry first continuous streaming of protocol data from PGY-SSMlite Protocol Analyzer to host system (using USB3.0 or GbE interface). Comprehensive decoding of data, protocol tests, and error analysis enables verification of communication of SD host and device.

  • Tunable Laser Hydrogen Chloride Analyzer

    TX-100 - HORIBA, Ltd.

    Laser HCl analyzer with a probe type optical system which employs direct insert method. TX-100 is suitable for monitoring HCl concentration in incineration plants and the control of HCl removal process in various industries including cement factories and petrochemical plants, etc.

  • RC BGA Interposer, LPDDR4 200-ball, Rigid, Connects Using 2x U4207A

    W6602A - Keysight Technologies

    The W6602A LPDDR4 rigid RC BGA interposer for LPDDR4 200-ball DRAM enables capture of simultaneous read and write traffic at data rates and has been tested to 3200 MT/s. Two U4207A zero Ω, 34-channel, soft touch pro, single-ended, 4 x 160-pin direct connect probes are required to connect the W6602A LPDDR4 BGA interposer into two U4164A logic analyzer modules. The W6602A LPDDR4 rigid RC BGA interposer allows signal access to the LPDDR4 signals critical to your debug and validation effort through a U4164A logic analyzer system. The probe works in existing designs and eliminates the need for up-front planning or redesign. The probe connects directly to the balls of the DRAM using a LPDDR4 200-ball riser (included) or an optional 3rd party socket (not provided), enabling operation and acquisition of LPDDR4 signals.

Get Help